1kV热缩终端和中间连接 |
|||||||
加工定制: |
否 |
品牌: |
沃特利 |
||||
型 号: |
WTL-N(W/J)SY(Z) - 1/*** |
材质: |
塑料 |
||||
耐 温: |
-50~105(℃) |
||||||
产品特点: |
|||||||
辐射交联热缩型电力电缆附件,是国内电缆附件行业中的最新产品。具有体积小、重量轻、性能可靠,适应性强、安装简便和价格便宜等特点。适用于各种电力电缆(交联电缆、塑料电缆和油浸电缆)的户内、户外终端、中间连接以及通信电缆连接、绝缘和各个领域的输配电工程。 |
|||||||
热缩型系列电力电缆附件产品型号表示方法:
|
|||||||
0.6/1kV热缩型系列产品规格表
|
|||||||
产品名称 |
型号规格 |
适用电缆规格 |
产品名称 |
型号规格 |
适用电缆规格 |
||
(mm2) |
(mm2) |
||||||
0.6/1kV热缩型单芯热缩户内终端 |
WTL-NSY-1/1×0 |
10-16 |
0.6/1kV热缩型单芯热缩中间连接 |
WTL-JSY-1/1×0 |
10-16 |
||
WTL-NSY-1/1×1 |
25-50 |
WTL-JSY-1/1×1 |
25-50 |
||||
WTL-NSY-1/1×2 |
70-120 |
WTL-JSY-1/1×2 |
70-120 |
||||
WTL-NSY-1/1×3 |
150-240 |
WTL-JSY-1/1×3 |
150-240 |
||||
WTL-NSY-1/1×4 |
300-400 |
WTL-JSY-1/1×4 |
300-400 |
||||
WTL-NSY-1/1×5 |
500-630 |
WTL-JSY-1/1×5 |
500-630 |
||||
0.6/1kV热缩型两芯热缩户内终端 |
WTL-NSY-1/2×0 |
10-16 |
0.6/1kV热缩型两芯热缩中间连接 |
WTL-JSY-1/2×0 |
10-16 |
||
WTL-NSY-1/2×1 |
25-50 |
WTL-JSY-1/2×1 |
25-50 |
||||
WTL-NSY-1/2×2 |
70-120 |
WTL-JSY-1/2×2 |
70-120 |
||||
WTL-NSY-1/2×3 |
150-240 |
WTL-JSY-1/2×3 |
150-240 |
||||
WTL-NSY-1/2×4 |
300-400 |
WTL-JSY-1/2×4 |
300-400 |
||||
0.6/1kV热缩型三芯热缩户内终端 |
WTL-NSY-1/3×0 |
10-16 |
0.6/1kV热缩型三芯热缩中间连接 |
WTL-JSY-1/3×0 |
10-16 |
||
WTL-NSY-1/3×1 |
25-50 |
WTL-JSY-1/3×1 |
25-50 |
||||
WTL-NSY-1/3×2 |
70-120 |
WTL-JSY-1/3×2 |
70-120 |
||||
WTL-NSY-1/3×3 |
150-240 |
WTL-JSY-1/3×3 |
150-240 |
||||
WTL-NSY-1/3×4 |
300-400 |
WTL-JSY-1/3×4 |
300-400 |
||||
0.6/1kV热缩型四芯热缩户内终端 |
WTL-NSY-1/4×0 |
10-16 |
0.6/1kV热缩型四芯热缩中间连接 |
WTL-JSY-1/4×0 |
10-16 |
||
WTL-NSY-1/4×1 |
25-50 |
WTL-JSY-1/4×1 |
25-50 |
||||
WTL-NSY-1/4×2 |
70-120 |
WTL-JSY-1/4×2 |
70-120 |
||||
WTL-NSY-1/4×3 |
150-240 |
WTL-JSY-1/4×3 |
150-240 |
||||
WTL-NSY-1/4×4 |
300-400 |
WTL-JSY-1/4×4 |
300-400 |
||||
0.6/1kV热缩型五芯热缩户内终端 |
WTL-NSY-1/5×0 |
10-16 |
0.6/1kV热缩型五芯热缩中间连接 |
WTL-JSY-1/5×0 |
10-16 |
||
WTL-NSY-1/5×1 |
25-50 |
WTL-JSY-1/5×1 |
25-50 |
||||
WTL-NSY-1/5×2 |
70-120 |
WTL-JSY-1/5×2 |
70-120 |
||||
WTL-NSY-1/5×3 |
150-240 |
WTL-JSY-1/5×3 |
150-240 |
||||
WTL-NSY-1/5×4 |
300-400 |
WTL-JSY-1/5×4 |
300-400 |
||||
技术指标: |
|||||||
测试项目 |
序号 |
实验项目 |
标准要求 |
实验结果 |
评定 |
||
0.6/1kV热缩终端和中间连接 |
1 |
5min工频耐压实验 |
8kV不闪烁、不击穿 |
8kV未发生闪烁、未发生击穿 |
通过 |
||
2 |
循环负荷实验(3次) |
加热,3h冷却,加热时导体温度75℃ |
5h加热,3h冷却,加热时导体温度75℃ |
由后续实验判定 |
|||
5 |
交流耐压15min |
2.5kV不闪络,不击穿 |
4.5kV,15min,组合试样未闪络和击穿 |
通过 |